Wagner de Aguiar Júnior, Brunela Pereira da Silva, Kazuko Uchikawa Graziano, 等. Effect of Cleaning Detergents on the Corrosion Resistance of AISI 420 Stainless Steel during Surgical Instrument Reprocessing[J]. Sterile Supply, 2026,5(2):117-126.
de Aguiar Júnior Wagner,Silva Brunela Pereira da,Graziano Kazuko Uchikawa,et al.Effect of Cleaning Detergents on the Corrosion Resistance of AISI 420 Stainless Steel during Surgical Instrument Reprocessing[J].Sterile Supply,2026,05(02):117-126.
Wagner de Aguiar Júnior, Brunela Pereira da Silva, Kazuko Uchikawa Graziano, 等. Effect of Cleaning Detergents on the Corrosion Resistance of AISI 420 Stainless Steel during Surgical Instrument Reprocessing[J]. Sterile Supply, 2026,5(2):117-126.DOI: 10.11910/j.issn.2791-2043.2026.2.06.
de Aguiar Júnior Wagner,Silva Brunela Pereira da,Graziano Kazuko Uchikawa,et al.Effect of Cleaning Detergents on the Corrosion Resistance of AISI 420 Stainless Steel during Surgical Instrument Reprocessing[J].Sterile Supply,2026,05(02):117-126.DOI: 10.11910/j.issn.2791-2043.2026.2.06.
Effect of Cleaning Detergents on the Corrosion Resistance of AISI 420 Stainless Steel during Surgical Instrument Reprocessing
To evaluate the resistance to localized corrosion of AISI 420 martensitic stainless steel used in surgical instruments when exposed to different cleaning detergent solutions.
Methods
2
An experimental laboratory study was conducted using AISI 420 stainless steel specimens. Corrosion behavior was evaluated by cyclic potentiodynamic polarization
in accordance with ASTM G61-86 (2024). Tests were performed in three solutions: alkaline detergent
enzymatic detergent
and disinfectant detergent
prepared in distilled-deionized water. Electrochemical measurements were carried out in a three-electrode cell with a saturated Ag/AgCl/KCl reference electrode at 40 ℃
simulating automated washer-disinfector conditions. Surface morphology after testing was analyzed using scanning electron microscopy.
Results
2
Higher resistance to localized corrosion was observed in alkaline conditions. The alkaline detergent showed stable passivation
absence of pitting potential
and high transpassive potential (E
transp
=1.200 V±0.016). The disinfectant detergent also demonstrated relatively high corrosion resistance
with elevated crevice potential (E
crevice
=1.056 V±0.078)
although localized attack was observed under crevice conditions. In contr
ast
the enzymatic detergent
with near-neutral pH
exhibited lower corrosion resistance
characterized by a defined pitting potential (E
pit
=0.835 V±0.049) and positive hysteresis. Surface analysis confirmed the presence of pitting and crevice corrosion in enzymatic and disinfectant solutions. These findings highlight the importance of detergent selection in preserving surgical instrument integrity and preventing corrosion during reprocessing.
关键词
Keywords
references
DALMAU A , RICHARD C , IGUAL – MUÑOZ A . Degradation mechanisms in martensitic stainless steels: Wear, corrosion and tribocorrosion appraisal [J ] . Tribology International , 2018 , 121 : 167 - 179 .
American Iron and Steel Institute . North American specification for the design of cold-formed steel structural members : AISI S100-12 (Supplement 1) [S ] . 2016 .
Standard Specification for Wrought Stainless Steels for Surgical Instruments : ASTM F899-20 [S ] . ASTM International , 2020 .
Standard Guide for Care and Handling of Stainless Steel Surgical Instruments : ASTM F1744-96(2016) [S ] . ASTM International , 2016 .
ZHOU Y Q , ENGELBERG D L . Accessing the full spectrum of corrosion behaviour of tempered type 420 stainless steel [J ] . Materials and Corrosion , 2021 , 72 ( 11 ): 1718 - 1729 .
RECLARU L , GRECU A F , GRECU D F , et al . Corrosion and ion release in 304L stainless steel biomedical stylets [J ] . Materials , 2025 , 18 ( 16 ): 3769 .
LUCAS T C , DE SOUZA M X , GUEDES H M , et al . Identification of physical and chemical deterioration in surgical instruments after reprocessing [J ] . Revista de Enfermagem Do Centro-Oeste Mineiro , 2018 , 8 : 1 - 8 .
Sherbakov AI , Dorofeeva VN , Korosteleva IG , et al . Inhibition of pitting corrosion of AISI 420 (40X13) stainless steel in low-mineralized water by sulphate ions [J ] . International Journal of Corrosion and Scale Inhibition , 2020 , 9 ( 2 ): 519 - 525 .
GOMES E T , DOS SANTOS R I , DOS SANTOS LOPES M G , et al . Integrity and functionality of surgical instruments in a public university hospital: A prospective study [J ] . Revista SOBECC , 2024 , 29 : e2429935 .
Aguiar Junior WA , Silva BP , Cruz AS , et al . Corrosion resistance and cytotoxicity of stainless steels exposed to chloride solutions [J ] . Revista SOBECC , 2024 , 29 : e2429908 .
Liu M , Lin S , Zhu H , et al . Comparison of the first cleaning quality effect of two different cleaning methods for metal precision surgical instruments [J ] . Sterile Supply , 2022 , 1 ( 2 ): 55 - 58 .
DE SOUZA R Q , GONÇALVES C R , IKEDA T I , et al . O impacto do último enxágue na citotoxicidade de produtos críticos passíveis de processamento [J ] . Revista da Escola de Enfermagem da USP , 2015 , 49 : 87 - 92 .
XU Y W , HUANG Z H , CORNER G . A study of the effect of clinical washing decontamination process on corrosion resistance of Martensitic Stainless Steel 420 [J ] . Bio-Medical Materials and Engineering , 2016 , 27 ( 4 ): 341 - 351 .
Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron-, Nickel-, or Cobalt-Based Alloys : ASTM G61-86(2024) [S ] . ASTM International , 2024 .
MAURICE V , MARCUS P . Progress in corrosion science at atomic and nanometric scales [J ] . Progress in Materials Science , 2018 , 95 : 132 - 171 .
ESMAILZADEH S , ALIOFKHAZRAEI M , SARLAK H . Interpretation of cyclic potentiodynamic polarization test results for study of corrosion behavior of metals: A review [J ] . Protection of Metals and Physical Chemistry of Surfaces , 2018 , 54 ( 5 ): 976 - 989 .
FRANKEL G S , LI T S , SCULLY J R . Perspective—Localized corrosion: Passive film breakdown vs pit growth stability [J ] . Journal of the Electrochemical Society , 2017 , 164 ( 4 ): C180 - C181 .
SPRY C C . Care and handling of basic surgical instruments [J ] . AORN Journal , 2007 , 86 ( S1 ): 77 - 81 .
RODRIGUES C A D , ENOKIBARA F , LEIVA T P , et al . Qualidade do aço inoxidável martensítico do tipo AISI-420 utilizado na confecção de ferramentas cirúrgicas [J ] . Rem: Revista Escola de Minas , 2009 , 62 ( 4 ): 475 - 480 .
Bruna CQ , Graziano KU . Performance evaluation of cleaning detergents: a proposal validation [J ] . Acta Paulista de Enfermagem , 2023 , 36 : eAPE00301 .
DE OLIVEIRA A C , MATI M L . Indicações e limitações dos diferentes detergentes utilizados no processamento de produtos para a saúde [J ] . Revista SOBECC , 2017 , 22 ( 2 ): 106 - 114 .
The trial reading is over, you can activate your VIP account to continue reading.
Dual-Robot Collaborative Automated Sterile Pack Storage System for the Central Sterile Supply Department: Design and Performance Validation
A Cross-Sectional Survey on Management and Processing Practices for Loaner Surgical Instruments and Implants Among 861 Hospitals in China
A Comparative Study on Application of Different Management Models for Surgical Instruments in Central Sterile Supply Department
Current Status Analysis of Infection Control Knowledge Among Central Sterile Supply Department Staff: A Cross-Sectional Study
Qualitative Study on Functional Quality Evaluation of Surgical Scissors Based on Different Stakeholder Perspectives
相关作者
Yabin Lai
Lingyan He
Xinxin Yang
Jin Wang
Huanxi Zhang
Ying Wang
Chunzi Cao
Yan Pan
相关机构
Honjo Medical Technology Co., Ltd.
Central Sterile Supply Department, Beijing Anzhen Hospital
Central Sterile Supply Department I, Hunan Provincial People’ s Hospital (The First Affiliated Hospital of HunanNormal University), No. 61 Jiefang West Road, Changsha City
School of Nursing, Pingdingshan University
Nursing Department, The First People’s Hospital of Chongqing High-tech Zone