Innovative Application of a Synergistic ATP Bioluminescence Assay–Video-in-Video Visualization–Traceability System for Closed-Loop Management of the Central Sterile Supply Department
TECHNOLOGICAL INNOVATION|Updated:2026-08-31
|
Innovative Application of a Synergistic ATP Bioluminescence Assay–Video-in-Video Visualization–Traceability System for Closed-Loop Management of the Central Sterile Supply Department
Sterile SupplyVol. 5, Issue 2, (2026)
Affiliations:
Central Sterile Supply Department, Xiangyang Central Hospital
Xiang Chen,Min Zhu.Innovative Application of a Synergistic ATP Bioluminescence Assay–Video-in-Video Visualization–Traceability System for Closed-Loop Management of the Central Sterile Supply Department[J].Sterile Supply,2026,05(02):109-116.
DOI:
Xiang Chen,Min Zhu.Innovative Application of a Synergistic ATP Bioluminescence Assay–Video-in-Video Visualization–Traceability System for Closed-Loop Management of the Central Sterile Supply Department[J].Sterile Supply,2026,05(02):109-116.DOI: 10.11910/j.issn.2791-2043.2026.2.05.
Innovative Application of a Synergistic ATP Bioluminescence Assay–Video-in-Video Visualization–Traceability System for Closed-Loop Management of the Central Sterile Supply Department
To investigate the effectiveness of the three-technology synergistic system integrating adenosine triphosphate (ATP) bioluminescence assay
video-in-video visualization inspection
and intelligent traceability in the closed-loop management of the Central Sterile Supply Department (CSSD)
and to establish a new intelligent
end-to-end
and traceable model for instrument cleaning quality control.
Methods
2
Reusable surgical instruments processed by the CSSD of our hospital from July 2024 to June 2025 were included in this study. A synergistic management system integrating ATP rapid primary screening
video-in-video visualization inspection
and intelligent end-to-end traceability was established. A
self-controlled before-and-after study design was employed
with instruments processed from July to December 2024 assigned to the pre-implementation group (
n
=12
560) and those processed from January to June 2025 assigned to the post-implementation group (
n
=18
920). Two groups were compared in terms of cleaning pass rate
detection rate of residues in cannulated instruments
quality issue traceability time
clinical department satisfaction with CSSD services
and healthcare-associated infection indicators.
Results
2
After implementation of the three-dimensional integrated technology
the overall instrument cleaning pass rate increased from 92.35% to 99.78% (
χ
²=347.26
p
<
0.05); the pass rate of cannulated instruments increased from 88.17% to 99.69% (
χ
²=298.51
p
<
0.05); the detection rate of biological/particulate residues in cannulated instruments decreased from 7.82% to 0.31% (
χ
²=265.38
p
<
0.05); average time required for quality issue traceability was reduced from (45.2±6.8) min to (8.3±2.1) min (
t
=42.17
p
<
0.05); and clinical department satisfaction scores increased from (91.6±3.2) to (98.9±1.1) (
t
=18.63
p
<
0.05).
Conclusion
2
The three-technology synergistic system integrating ATP bioluminescence assay
video-in-video visualization
and intelligent traceability enables closed-loop management of cleaning quality characterized by “rapid detection - precise verification - end-to-end traceability - continuous improvement”. It can significantly enhance the quality and safety management of sterile supply services
providing innovative technical support for the prevention and control of healthcare-associated infections.
关键词
Keywords
references
National Health and Family Planning Commission of the People’s Republic of China . CSSD-Part 3: Standard for Monitoring the Effects of Cleaning, Disinfection and Sterilization : WS 310.3—2016 [S ] . Beijing : Standards Press of China , 2017 .
National Health and Family Planning Commission of the People’s Republic of China . CSSD-Part 1: Management Standard : WS 310.1—2016 [S ] . Beijing : Standards Press of China , 2017 .
Li AQ , Ren XF , Tang S , et al . Effect of centralized management in the central sterile supply department on the cleaning efficacy of pediatric bronchoscopes [J ] . Chinese Journal of Nosocomiology , 2023 , 33 ( 6 ): 952 - 955 .
HERVÉ R , KEEVIL C W . Current limitations about the cleaning of luminal endoscopes [J ] . Journal of Hospital Infection , 2013 , 83 ( 1 ): 22 - 29 .
Zhu J , Wang JL . Comparison of three different detection methods for evaluating the cleaning efficacy of rigid endoscopes in the central sterile supply department [J ] . China Medical Device Information , 2024 , 30 ( 1 ): 168 - 170 .
Liu JY , Ma L , Xie HJ , et al . Application of borescopes in quality inspection of lumen instrument cleaning [J ] . China Medical Equipment , 2023 , 20 ( 2 ): 156 - 159 .
Shi XY , Ruan HM , Liu LW , et al . Application of traceability management and quality control in the sterile processing and supply of surgical instruments [J ] . China Medical Equipment , 2021 , 18 ( 5 ): 124 - 128 .
NUGENT P G , MODI T , MCLEOD N , et al . Application of rapid read-out cleaning indicators for improved process control in hospital sterile services departments [J ] . Journal of Hospital Infection , 2013 , 84 ( 1 ): 59 - 65 .
Chang HC , Zou LJ , Dai HX , et al . Dynamic monitoring of the cleaning process of endoscopic instruments using ATP bioluminescence [J ] . Chinese Nursing Management , 2010 , 10 ( 6 ): 52 - 53 .
Zhou WF , Zhang LY , Liu J , et al . Application of portable luminal light-guiding device in cleaning quality assessment of luminal instruments [J ] . Sterile Supply , 2024 , 6 ( 1 ): 45 - 52 .
Su YY , Hu JB , Shen HJ . Application of electronic projection otoscopy in detecting the internal cleaning quality of rigid endoscopic instruments [J ] . Chinese Science and Technology Journal Database (Full-text Version)-Medicine and Health , 2023 ( 5 ): 39 - 41 .
Zhao CY . Information-based practice for the prevention and control of healthcare-associated infections related to reusable medical devices [J ] . Chinese Nursing Research , 2020 , 34 ( 20 ): 3731 - 3733 .
Jiang LH , Yao SX , Yang YJ , et al . Application of a traceable information system in the management of the central sterile supply department [J ] . Medical Equipment , 2019 , 32 ( 20 ): 63 .
Li XP , Fang L . Effect of information-based closed-loop management on the efficiency and effectiveness of sterile package distribution [J ] . China Medical Devices , 2022 , 37 ( 1 ): 132 - 134 .
The trial reading is over, you can activate your VIP account to continue reading.
Application Progress of Failure Mode and Effects Analysis in the Risk Management of Central Sterile Supply Departments
Effects of Digital Closed-loop Traceability Management on Surgical Instrument Coordination Between the Central Sterile Supply Department and the Operating Room
An AI-Assisted Traceability System for Risk Alerting and Efficiency Enhancement in the Central Sterile Supply Department: A Self-Controlled Study
Dual-Mode QR Code and NFC Management Improves Equipment Full Life-cycle Traceability Efficiency in Central Sterile Supply Department
Effect of Different Moisturizing Agents on Cleaning Quality of Rigid Endoscopes: A Meta-Analysis
Related Author
Xiaoying He
Yuanyuan Song
Pengqin Gao
Jun Wang
Xia Wu
Dan Li
Jing Che
Yan Zeng
Related Institution
Central Sterile Supply Department, Affiliated Hospital of Panzhihua University
The People’s Hospital of Leshan
Shenzhen Traditional Chinese Medicine Hospital
Jingmen Central Hospital
Central Sterile Supply Department, Taihe Hospital, Shiyan City