Guo Lili,Lyu Jingyi,Huang Ying.Bundled Management for Control of Environmental Contamination by Multidrug-Resistant Organisms in ICU[J].Sterile Supply,2026,05(01):59-65.
DOI:
Guo Lili,Lyu Jingyi,Huang Ying.Bundled Management for Control of Environmental Contamination by Multidrug-Resistant Organisms in ICU[J].Sterile Supply,2026,05(01):59-65.DOI: 10.11910/j.issn.2791-2043.2026.1.07.
Bundled Management for Control of Environmental Contamination by Multidrug-Resistant Organisms in ICU
This study aims to evaluate the effectiveness of bundled management measures in controlling environmental contamination by multidrug-resistant organisms (MDROs) in the intensive care unit (ICU)
and to provide a practical basis for reducing the risk of MDRO contamination in the ICU environment and decreasing the incidence of nosocomial infections.
Methods
2
Patients colonized or infected with MDROs in the ICU were screened using the hospital-acquired infection surveillance system. Environmental hygiene monitoring was performed on high-frequency contact surfaces of MDRO patients
healthcare workers’ hands
medical textiles
and sinks. The fluorescent labeling method was employed to monitor the implementation of surface cleaning and disinfection in the ICU. Targeted bundled rectification measures were then implemented
and environmental hygiene monitoring and evaluation were repeated after four months.
Results
2
A total of 90 samples were collected from high-frequency contact surfaces
textiles
and sinks in the ICU both before and after the intervention. Following the implementation of targeted rectification measures
the detection rate of microbial specimens decreased from 71.11% to 17.78% with a statistically significant difference (
P
<
0.05). For environmental cleaning monitored using the fluorescent labeling method
960 points were marked before the intervention
of which 367 were cleared; after the intervention
950 points were marked
and 830 were cleared. The clearance rate increased from 38.23% before the intervention to 87.36% after the intervention
and the difference was statistically significant (
P
<
0.05).
Conclusion
2
Implementation of corresponding environmental rectification measures can reduce environmental surface contamination by MDROs in the ICU
effectively interrupt transmission routes
and decrease the incidence of nosocomial infections.
关键词
Keywords
references
World Health Organization . Antimicrobial resistance [EB/OL ] . ( 2023-11-21 ) [ 2025-01-21 ] .
China Antimicrobial Resistance Surveillance System . Surveillance on antimicrobial resistance of bacteria in different levels of hospitals:surveillance report from China Antimicrobial Resistance Surveillance System in 2014—2019 [J ] . Chinese Journal of Infection Control , 2021 , 20 ( 2 ): 95 - 111 .
National Health Commission of the People’s Republic of China . Medical quality control indicators for healthcare-associated infection management (2024 Edition) [J ] . Chinese Journal of Infection Control , 2024 , 23 ( 6 ): 784 - 786 .
Zhang C , Peng Y , Luo XQ , et al . Distribution and drug resistance of pathogens isolated from intensive care unit of a hospital in 2015—2019 [J ] . Chinese Journal of Nosocomiology , 2021 , 31 ( 21 ): 3240 - 3245 .
Sun H , Zhang XQ , Zhou DM . Investigation and control measures on multidrug-resistant Acinetobacter baumannii nosocomial infection outbreak in comprehensive ICU [J ] . Chinese Journal of Disinfection , 2014 , 31 ( 3 ): 268 - 270, 273 .
Shi XL , Shi JM , Shen HW , et al . Summary of best evidence for prevention and control of multidrug-resistant organism infection in adult ICU [J ] . Chinese Journal of Nursing , 2024 , 59 ( 6 ): 727 - 735 .
Shi YY , Liu WP , Guo HL . Analysis of effect of hospital infection knowledge system training for cleaning staff [J ] . Chinese Nursing Research , 2017 , 31 ( 23 ): 2909 - 2910 .
Hu HF , Guo JF , Kong L , et al . Application of fluorescence marker in assessment and improvement of environmental cleaning quality of hospitals [J ] . Chinese Journal of Nosocomiology , 2017 , 27 ( 18 ): 4261 - 4264 .
Zha P , Zhang XX , Kang AL , et al . Effect of Fluorescent Labeling Method on Monitoring Surface Cleaning and Disinfection of Objects in the PIVAS [J ] . China Pharmaceuticals , 2021 , 30 ( 22 ): 40 - 42 .
Qin TZ , Liu Y , Hao YW , et al . The effectiveness of fluorescence labeling-based assay bundle intervention in the prevention and control of multidrug-resistant organism infection [J ] . Chinese Journal of Infection Control , 2024 , 23 ( 2 ): 225 - 230 .
Chen W , Chen XE , Jin HL , et al . Investigation of bacterial contamination on object surface in intensive care unit [J ] . Chinese Journal of Nosocomiology , 2016 , 26 ( 24 ): 5740 - 5741, 5750 .
Sun L , Fei N , Man SJ , et al . Analysis on prevention and control measures and disinfection effect of multi-drug-resistant bacteria [J ] . Chinese Journal of Disinfection , 2022 , 39 ( 8 ): 587 - 589+592 .