1.School of Energy and Environment, Southeast University, 210000, Nanjing, Jiangsu, China
2.Jiangsu Women and Children Health Hospital, 210000, Nanjing, Jiangsu, China
3.Center of Science and Technology Development, Department of Housing and Urban-Rural Development of Jiangsu Province, 210000, Nanjing, Jiangsu, China
纸质出版:2023-03-15
Scan QR Code
Danting Luo, Yubin Zhang, Yihua Zhao, 等. Interpretation of DB32/T 4176-2021
Luo Danting,Zhang Yubin,Zhao Yihua,et al.Interpretation of DB32/T 4176-2021 Technical specification for indoor air quality monitoring system in public buildings[J].Sterile Supply,2023,02(01):1-7.
Danting Luo, Yubin Zhang, Yihua Zhao, 等. Interpretation of DB32/T 4176-2021
Luo Danting,Zhang Yubin,Zhao Yihua,et al.Interpretation of DB32/T 4176-2021 Technical specification for indoor air quality monitoring system in public buildings[J].Sterile Supply,2023,02(01):1-7. DOI: 10.11910/j.issn.2791-2043.2023.1.01.
The ongoing COVID-19 pandemic reveals the shortages of our worrisome indoor air quality. Indoor air quality monitoring systems provide a promising strategy
and a systematic guideline for monitoring systems is vital. The new publication of
DB32/T 4176-2021
specification
[
1
1
]
is the first systematic guideline to help standardize air quality monitoring systems in public spaces. In order to facilitate the implementation and promotion of this specification
the revision background
drafting principles
and basis for the preparation and revision of main technical indicators were interpreted. Applying this specification helps to improve the operation and maintenance level
improve the indoor air quality of public buildings
and ensure the respiratory health of every occupant.
China Jiangsu standard . DB32/T 4176-2021 Technical specification for indoor air quality monitoring system in public buildings (2021) .
Mathieu , E. et al . Coronavirus Pandemic (COVID-19) , https://ourworldindata.org/coronavirus. (Last Update: 19 Nov. 2020) Accessed: 20 Nov. , 2020 .
Qian , H. et al . Indoor transmission of SARS-CoV-2 . Indoor Air 31 , 639 - 645 , doi: 10.1111/ina.12766 (2021 http://dx.doi.org/10.1111/ina.12766(2021 ).
Bulfone T. C. , Malekinejad M. , Rutherford G . W . & Razani , N . Outdoor Transmission of SARS-CoV-2 and Other Respiratory Viruses: A Systematic Review. J Infect Dis 223, 550- 561 , ( 2021 ). doi: 10.1093/infdis/jiaa742 http://dx.doi.org/10.1093/infdis/jiaa742
Li , Y. et al . Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant . Build. Environ . 196 , 107788 , doi:10.1016/j.buildenv.2021.107788 (2021).
Miller , S. L. et al . Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event . Indoor Air 31 , 314 - 323 , doi: 10.1111/ina.12751 (2021 http://dx.doi.org/10.1111/ina.12751(2021 ).
Matsumura , Y. et al . High mortality and morbidity among vaccinated residents infected with the SARS-CoV-2 Omicron variant during an outbreak in a nursing home in Kyoto City, Japan . American journal of infection control , doi: 10.1016/j.ajic.2022.09.007 (2022 http://dx.doi.org/10.1016/j.ajic.2022.09.007(2022 ).
Song H. , Jia Z. , Jin Z . & Liu, S . Estimation of COVID-19 outbreak size in Harbin , China. Nonlinear Dynamics 106, 1229- 1237 , ( 2021 ). doi: 10.1007/s11071-021-06406-2 http://dx.doi.org/10.1007/s11071-021-06406-2
Vardoulakis , S. et al . Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review . International Journal of Environmental Research and Public Health 17 , doi: 10.3390/ijerph17238972 (2020 http://dx.doi.org/10.3390/ijerph17238972(2020 ).
Xiang J. , Seto E. , Mo J. , Zhang J . & Zhang, Y . Impacts of implementing Healthy Building guidelines for daily PM2.5 limit on premature deaths and economic losses in urban China : A population-based modeling study. Environment International 147 , doi: 10.1016/j.envint.2020.106342 (2021 http://dx.doi.org/10.1016/j.envint.2020.106342(2021 ).
Zhang Y. , Mo , J. & Weschler, C. J. Reducing Health Risks from Indoor Exposures in Rapidly Developing Urban China . Environmental Health Perspectives 121 , 751 - 755 , ( 2013 ).doi:10.1289/ehp.1205983
Anderson J. O. , Thundiyil J. G. & Stolbach A. Clearing the Air: A Review of the Effects of Particulate Matter Air Pollution on Human Health . Journal of Medical Toxicology 8 , 166 - 175 , (2012).doi:10.1007/s13181-011-0203-1
Raaschou-Nielsen , O. et al . Air pollution and lung cancer incidence in 17 European cohorts: prospective analyses from the European Study of Cohorts for Air Pollution Effects (ESCAPE) . Lancet Oncology 14 , 813 - 822 , doi: 10.1016/s1470-2045(13)70279-1 (2013 http://dx.doi.org/10.1016/s1470-2045(13)70279-1(2013 ).
Xu X. , Zhang J. , Yang X. , Zhang Y . & Chen, Z . The Role and Potential Pathogenic Mechanism of Particulate Matter in Childhood Asthma : A Review and Perspective. Journal of Immunology Research 2020 , doi: 10.1155/2020/8254909 (2020 http://dx.doi.org/10.1155/2020/8254909(2020 ).
Lamplugh , A. et al . Occupational exposure to volatile organic compounds and health risks in Colorado nail salons . Environmental Pollution 249 , 518 - 526 , doi: 10.1016/j.envpol.2019.03.086 (2019 http://dx.doi.org/10.1016/j.envpol.2019.03.086(2019 ).
Liu , N. et al . Indoor exposure levels and risk assessment of volatile organic compounds in residences, schools, and offices in China from 2000 to 2021: A systematic review . 32 , e 13091 , doi:10.1111/ina.13091 (2022).
Zhao B. & Wu J. Particulate pollution in ventilated space: Analysis of influencing factors . Journal of Hazardous Materials 163 , 454 - 462 , ( 2009 ).doi:10.1016/j.jhazmat.2008.06.118
Breen , M. S. et al . A review of air exchange rate models for air pollution exposure assessments . Journal of Exposure Science and Environmental Epidemiology 24 , 555 - 563 , doi: 10.1038/jes.2013.30 (2014 http://dx.doi.org/10.1038/jes.2013.30(2014 ).
Chinese standard . GB 37488-2019 Code for fire protection design of buildings (2019) .
European standard . EN 16798-1:2019 Energy performance of buildings - Ventilation for buildings . ( 2019 ).
ISO . ISO 1772-1:2017(en) Energy performance of buildings—Indoor environmental quality . the International Organization for Standardization . ( 2017 ).
ASHRAE . 2019 ASHRAE Handbook—Heating, Ventilation, and Air-Conditioning Applications . American Society of Heating , Ventilating, and Air-Conditionin g Engineers. ( 2019 ).
ASHRAE . ASHRAE Standard 62 . 1 - 2022 . 2022.
Publications W . R . Air Quality Guidelines for Europe . ( 1987 ).
Chinese stanard . GB/T 18883-2022 Standards for indoor air quality . ( 2022 ).
Liu , W. et al . Indoor exposure to phthalates and its burden of disease in China . Indoor Air 32 , doi: 10.1111/ina.13030 (2022 http://dx.doi.org/10.1111/ina.13030(2022 ).
Yang F. , Liu , C. & Qian, H. Comparison of indoor and outdoor oxidative potential of PM2.5: pollution levels , temporal patterns, and key constituents. Environment International 155 , doi: 10.1016/j.envint.2021.106684 (2021). http://dx.doi.org/10.1016/j.envint.2021.106684(2021).
Wang S. , Qian H. , Sun Z. , Cao G . & Ding, P . Comparison of airborne bacteria and fungi in different types of buildings in a temperate climate zone city , Kunming, China. Indoor and Built Environment 31, 1949 -1962, ( 2022 ). doi: 10.1177/1420326x221082198 http://dx.doi.org/10.1177/1420326x221082198
Cui S. , Cohen M. , Stabat P . & Marchio, D . CO2 tracer gas concentration decay method for measuring air change rate. Building and Environment 84 , 162- 169 , ( 2015 ). doi: 10.1016/j.buildenv.2014.11.007 http://dx.doi.org/10.1016/j.buildenv.2014.11.007
Hu H. , Huang X. , Zhao Y. , Qian H . & Liu, C . A new PM2.5-based PM-up method to measure non-mechanical ventilation rate in buildings. Journal of Building Engineering 52 , doi: 10.1016/j.jobe.2022.104351 (2022 http://dx.doi.org/10.1016/j.jobe.2022.104351(2022 ).
Morawska , L. et al . Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone? Environment International 116 , 286 - 299 , doi: 10.1016/j.envint.2018.04.018 (2018 http://dx.doi.org/10.1016/j.envint.2018.04.018(2018 ).
Vinh Van T. , Park , D. & Lee , Y.-C. Indoor Air Pollution , Related Human Diseases , and Recent Trends in the Control and Improvement of Indoor Air Quality . International Journal of Environmental Research and Public Health 17 , doi: 10.3390/ijerph17082927 (2020 http://dx.doi.org/10.3390/ijerph17082927(2020 ).
Persily A. & de Jonge L. Carbon dioxide generation rates for building occupants . Indoor Air 27 , 868 - 879 , ( 2017 ).doi:10.1111/ina.12383
Chinese standard . GB 50016-2016 Code for fire protection design of buildings (2016) .
Chinese standard . GB 3095-2012 Ambient air quality standards . ( 2012 ).
Chinese environmental protection industry standard . HJ 633-2012 Technical regulation on ambient air quality index . ( 2012 ).
Chinese civil architectural electrical design standard . JGJ/T 436-2018 Technical standard for interior decoration pollution control of residential buildings . ( 2018 ).
Chinese civil architectural electrical design standard . JGJ/T 461-2019 Design standard for controlling indoor air quality of public building . ( 2019 ).